The next steps are to manually set up the main program that will handle the robot movements:

1.Add the declaration of the following global variables:           
To do so, locate and modify the file “KRC:\R1\SYSTEM\$CONFIG.DAT” via KUKA HMI. The folder “KRC:\R1\” can also be accessed from the C:\ drive at the following Windows path: “C:\KRC\ROBOTER\KRC\”.

INT COM_ACTION=0

INT COM_ACTCNT=0

REAL COM_ROUNDM=0

REAL COM_VALUE1=0

REAL COM_VALUE2=0

REAL COM_VALUE3=0

REAL COM_VALUE4=0

DECL E6AXIS COM_E6AXIS

DECL FRAME COM_FRAME

DECL POS COM_POS

DECL E6POS COM_E6POS

2.Copy the KUKA SRC program RoboDKsyncVER.src to the folder KRC\R1\PROGRAM. The VER suffix in the file name denotes the version of the program (for example, RoboDKsync543.src).

3.Manually start the RoboDKsyncVER.src program to make the robot listen for commands coming from the computer.